fix(gateway): request graceful Windows shutdown (#6353)
* fix(gateway): request graceful Windows shutdown * docs(cli): simplify Windows gateway stop guidance * test(gateway): compare native Windows owner SIDs
This commit is contained in:
1 parent
fd30fda8a2
commit
73a55e0b2f
7 files changed
+554
-25
No files matched your search
@@ -170,6 +170,8 @@ First-run WebUI setup binds to `127.0.0.1` by default. Use manual configuration
|
||||
| `nanobot gateway install-service --dry-run` | Preview the generated service file and system commands |
|
||||
| `nanobot gateway uninstall-service` | Remove the installed system service |
|
||||
|
||||
On Windows, `gateway stop` waits up to `--timeout` seconds (default: 20) for the gateway to stop normally. If a forced stop is needed, the command displays a warning. Forced stops can interrupt active work.
|
||||
|
||||
For custom instances, pass the same selector flags after the management subcommand, as shown below. `--config` and `--workspace` before a management subcommand are rejected with a usage error; they are not inherited.
|
||||
|
||||
```bash
|
||||
|
||||
@@ -980,6 +980,10 @@ def _run_gateway(
|
||||
logger.info("Last local client disappeared; stopping on-demand gateway")
|
||||
|
||||
tasks.extend([
|
||||
asyncio.create_task(
|
||||
gateway_runtime.wait_for_shutdown_request(shutdown_event),
|
||||
name="nanobot-gateway-stop-request",
|
||||
),
|
||||
asyncio.create_task(
|
||||
watch_config_file(
|
||||
Path(config_path),
|
||||
|
||||
@@ -20,10 +20,12 @@ from datetime import UTC, datetime
|
||||
from pathlib import Path
|
||||
from typing import Any, Generator, Literal, cast
|
||||
|
||||
from filelock import FileLock
|
||||
from filelock import FileLock, Timeout
|
||||
from loguru import logger
|
||||
|
||||
from nanobot.config.home import get_selected_home_path
|
||||
from nanobot.config.paths import get_data_dir
|
||||
from nanobot.gateway.windows_shutdown import WindowsShutdownEvent, request_windows_shutdown
|
||||
from nanobot.process_runtime import (
|
||||
ManagedProcessRuntime,
|
||||
ProcessResult,
|
||||
@@ -235,6 +237,7 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]):
|
||||
subprocess_run=subprocess_run,
|
||||
sleep=sleep,
|
||||
)
|
||||
self._shutdown_signal: WindowsShutdownEvent | None = None
|
||||
|
||||
def _build_child_command(self, options: GatewayStartOptions) -> list[str]:
|
||||
return build_gateway_command(self.python_executable, options)
|
||||
@@ -339,12 +342,66 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]):
|
||||
|
||||
@contextmanager
|
||||
def foreground_instance(self, options: GatewayStartOptions) -> Generator[None]:
|
||||
"""Publish this foreground gateway while it is available to local clients."""
|
||||
self._claim_current_process(options)
|
||||
"""Publish this process and own its stop signal across asyncio.run()."""
|
||||
shutdown_signal = None
|
||||
if self.platform_name == "Windows" and os.name == "nt":
|
||||
identity = self.process_identity(os.getpid())
|
||||
if not isinstance(identity, str):
|
||||
raise OSError("Cannot identify the gateway process for Windows shutdown")
|
||||
shutdown_signal = WindowsShutdownEvent(os.getpid(), identity)
|
||||
self._shutdown_signal = shutdown_signal
|
||||
try:
|
||||
yield
|
||||
self._claim_current_process(options)
|
||||
try:
|
||||
yield
|
||||
finally:
|
||||
self._release_current_process()
|
||||
finally:
|
||||
self._release_current_process()
|
||||
self._shutdown_signal = None
|
||||
if shutdown_signal is not None:
|
||||
shutdown_signal.close()
|
||||
|
||||
async def wait_for_shutdown_request(self, shutdown_event: asyncio.Event) -> None:
|
||||
"""Bridge the local Windows signal to the application's existing shutdown."""
|
||||
signal = self._shutdown_signal
|
||||
if signal is None:
|
||||
return
|
||||
waiter = asyncio.create_task(asyncio.to_thread(signal.wait))
|
||||
try:
|
||||
await asyncio.shield(waiter)
|
||||
logger.info("Gateway shutdown requested by local CLI")
|
||||
shutdown_event.set()
|
||||
finally:
|
||||
# Cancelling to_thread alone leaves its native wait alive. Wake it
|
||||
# before asyncio.run drains the executor and the owner closes the handle.
|
||||
signal.signal()
|
||||
await waiter
|
||||
|
||||
def _terminate_windows(self, pid: int, *, timeout_s: int) -> bool:
|
||||
state = self._read_state()
|
||||
identity = self._process_identity(pid)
|
||||
if identity is None:
|
||||
return not self._is_pid_running(pid)
|
||||
if self._process_identity_match(state, pid) != "match":
|
||||
return False
|
||||
requested = False
|
||||
if isinstance(identity, str) and state is not None:
|
||||
try:
|
||||
requested = request_windows_shutdown(pid, identity, state.get("shutdown_token"))
|
||||
except OSError as exc:
|
||||
logger.warning("Could not request gateway shutdown: {}", exc)
|
||||
if requested and self._wait_for_exit(pid, timeout_s):
|
||||
return True
|
||||
current_identity = self._process_identity(pid)
|
||||
if current_identity is None:
|
||||
return not self._is_pid_running(pid)
|
||||
if current_identity != identity:
|
||||
return False
|
||||
if requested:
|
||||
logger.warning("Gateway did not exit within {}s; forcing PID tree {}", timeout_s, pid)
|
||||
else:
|
||||
logger.warning("Gateway shutdown signal unavailable; forcing PID tree {}", pid)
|
||||
return super()._terminate_windows(pid, timeout_s=timeout_s)
|
||||
|
||||
def _claim_current_process(self, options: GatewayStartOptions) -> GatewayLaunchMode:
|
||||
lease = GatewayClientLease(self, kind="gateway-foreground")
|
||||
@@ -389,6 +446,9 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]):
|
||||
state.pop("pending_pid_handoff", None)
|
||||
state.pop("stable_identity", None)
|
||||
state.update(self.process_identity_record(pid))
|
||||
state.pop("shutdown_token", None)
|
||||
if self._shutdown_signal is not None:
|
||||
state["shutdown_token"] = self._shutdown_signal.token
|
||||
self._write_state(state)
|
||||
if launch_mode == "foreground":
|
||||
lease._try_mark_persistent_locked()
|
||||
@@ -521,7 +581,13 @@ class GatewayClientLease:
|
||||
|
||||
def begin_orphan_shutdown(self) -> bool:
|
||||
"""Commit shutdown only while an on-demand gateway still has no clients."""
|
||||
with self.transition_lock, self.lifecycle_lock, self.lock:
|
||||
# Explicit stop holds this lock while waiting for us to exit. Never
|
||||
# block the gateway loop (or an executor being drained) behind it.
|
||||
try:
|
||||
transition = self.transition_lock.acquire(timeout=0)
|
||||
except Timeout:
|
||||
return False
|
||||
with transition, self.lifecycle_lock, self.lock:
|
||||
state = self._live_state()
|
||||
if not bool(state.get("auto_stop")) or self._clients(state):
|
||||
self._write_or_clear(state)
|
||||
|
||||
@@ -0,0 +1,149 @@
|
||||
"""User-private, process-bound Windows gateway shutdown signals."""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import ctypes
|
||||
import re
|
||||
import uuid
|
||||
from collections.abc import Generator
|
||||
from contextlib import contextmanager
|
||||
from ctypes import wintypes
|
||||
from functools import lru_cache
|
||||
from typing import Any
|
||||
|
||||
|
||||
class _SecurityAttributes(ctypes.Structure):
|
||||
_fields_ = [
|
||||
("length", wintypes.DWORD),
|
||||
("descriptor", wintypes.LPVOID),
|
||||
("inherit", wintypes.BOOL),
|
||||
]
|
||||
|
||||
|
||||
@lru_cache(maxsize=1)
|
||||
def _kernel32() -> Any:
|
||||
kernel = ctypes.WinDLL("kernel32", use_last_error=True)
|
||||
kernel.GetCurrentProcess.restype = wintypes.HANDLE
|
||||
kernel.CreateEventW.argtypes = [
|
||||
ctypes.POINTER(_SecurityAttributes), wintypes.BOOL, wintypes.BOOL, wintypes.LPCWSTR,
|
||||
]
|
||||
kernel.CreateEventW.restype = wintypes.HANDLE
|
||||
kernel.OpenEventW.argtypes = [wintypes.DWORD, wintypes.BOOL, wintypes.LPCWSTR]
|
||||
kernel.OpenEventW.restype = wintypes.HANDLE
|
||||
kernel.SetEvent.argtypes = [wintypes.HANDLE]
|
||||
kernel.SetEvent.restype = wintypes.BOOL
|
||||
kernel.WaitForSingleObject.argtypes = [wintypes.HANDLE, wintypes.DWORD]
|
||||
kernel.WaitForSingleObject.restype = wintypes.DWORD
|
||||
kernel.CloseHandle.argtypes = [wintypes.HANDLE]
|
||||
kernel.CloseHandle.restype = wintypes.BOOL
|
||||
kernel.LocalFree.argtypes = [wintypes.LPVOID]
|
||||
kernel.LocalFree.restype = wintypes.LPVOID
|
||||
return kernel
|
||||
|
||||
|
||||
@contextmanager
|
||||
def _private_security() -> Generator[_SecurityAttributes]:
|
||||
kernel = _kernel32()
|
||||
security = ctypes.WinDLL("advapi32", use_last_error=True)
|
||||
security.OpenProcessToken.argtypes = [
|
||||
wintypes.HANDLE, wintypes.DWORD, ctypes.POINTER(wintypes.HANDLE),
|
||||
]
|
||||
security.OpenProcessToken.restype = wintypes.BOOL
|
||||
security.GetTokenInformation.argtypes = [
|
||||
wintypes.HANDLE, ctypes.c_int, wintypes.LPVOID, wintypes.DWORD,
|
||||
ctypes.POINTER(wintypes.DWORD),
|
||||
]
|
||||
security.GetTokenInformation.restype = wintypes.BOOL
|
||||
security.ConvertSidToStringSidW.argtypes = [
|
||||
wintypes.LPVOID, ctypes.POINTER(wintypes.LPWSTR),
|
||||
]
|
||||
security.ConvertSidToStringSidW.restype = wintypes.BOOL
|
||||
security.ConvertStringSecurityDescriptorToSecurityDescriptorW.argtypes = [
|
||||
wintypes.LPCWSTR, wintypes.DWORD, ctypes.POINTER(wintypes.LPVOID), wintypes.LPVOID,
|
||||
]
|
||||
security.ConvertStringSecurityDescriptorToSecurityDescriptorW.restype = wintypes.BOOL
|
||||
token = wintypes.HANDLE()
|
||||
if not security.OpenProcessToken(kernel.GetCurrentProcess(), 0x0008, ctypes.byref(token)):
|
||||
raise ctypes.WinError()
|
||||
sid_text = wintypes.LPWSTR()
|
||||
descriptor = wintypes.LPVOID()
|
||||
try:
|
||||
size = wintypes.DWORD()
|
||||
security.GetTokenInformation(token, 1, None, 0, ctypes.byref(size)) # TokenUser
|
||||
if not size.value:
|
||||
raise ctypes.WinError()
|
||||
user = ctypes.create_string_buffer(size.value)
|
||||
if not security.GetTokenInformation(token, 1, user, len(user), ctypes.byref(size)):
|
||||
raise ctypes.WinError()
|
||||
sid = ctypes.cast(user, ctypes.POINTER(wintypes.LPVOID))[0]
|
||||
if not security.ConvertSidToStringSidW(sid, ctypes.byref(sid_text)):
|
||||
raise ctypes.WinError()
|
||||
if not security.ConvertStringSecurityDescriptorToSecurityDescriptorW(
|
||||
f"O:{sid_text.value}D:P(A;;GA;;;{sid_text.value})", 1,
|
||||
ctypes.byref(descriptor), None,
|
||||
):
|
||||
raise ctypes.WinError()
|
||||
yield _SecurityAttributes(ctypes.sizeof(_SecurityAttributes), descriptor, False)
|
||||
finally:
|
||||
if descriptor:
|
||||
kernel.LocalFree(descriptor)
|
||||
if sid_text:
|
||||
kernel.LocalFree(sid_text)
|
||||
kernel.CloseHandle(token)
|
||||
|
||||
|
||||
def _event_name(pid: int, identity: str, token: str) -> str:
|
||||
return rf"Local\nanobot-gateway-stop-{pid}-{identity}-{token}"
|
||||
|
||||
|
||||
class WindowsShutdownEvent:
|
||||
"""Own one latched signal; close only after the native waiter has drained."""
|
||||
|
||||
def __init__(self, pid: int, identity: str) -> None:
|
||||
self.token = uuid.uuid4().hex
|
||||
kernel = _kernel32()
|
||||
with _private_security() as security:
|
||||
ctypes.set_last_error(0)
|
||||
handle = kernel.CreateEventW(
|
||||
ctypes.byref(security), True, False, _event_name(pid, identity, self.token),
|
||||
)
|
||||
error = ctypes.get_last_error()
|
||||
if not handle:
|
||||
raise ctypes.WinError(error)
|
||||
if error == 183: # ERROR_ALREADY_EXISTS: the requested DACL was not applied.
|
||||
kernel.CloseHandle(handle)
|
||||
raise OSError("Gateway shutdown event already exists")
|
||||
self._handle: int | None = int(handle)
|
||||
|
||||
def wait(self) -> None:
|
||||
"""Block a worker, never the event loop; signal() also wakes cancellation."""
|
||||
if _kernel32().WaitForSingleObject(self._handle, 0xFFFFFFFF) != 0:
|
||||
raise ctypes.WinError()
|
||||
|
||||
def signal(self) -> None:
|
||||
if not _kernel32().SetEvent(self._handle):
|
||||
raise ctypes.WinError()
|
||||
|
||||
def close(self) -> None:
|
||||
if self._handle is not None:
|
||||
_kernel32().CloseHandle(self._handle)
|
||||
self._handle = None
|
||||
|
||||
|
||||
def request_windows_shutdown(pid: int, identity: str, token: object) -> bool:
|
||||
"""Signal only a validated token in this exact process-birth namespace."""
|
||||
if not isinstance(token, str) or re.fullmatch(r"[0-9a-f]{32}", token) is None:
|
||||
return False
|
||||
kernel = _kernel32()
|
||||
handle = kernel.OpenEventW(0x0002, False, _event_name(pid, identity, token))
|
||||
if not handle:
|
||||
error = ctypes.get_last_error()
|
||||
if error == 2: # The process exited, or never published this event.
|
||||
return False
|
||||
raise ctypes.WinError(error)
|
||||
try:
|
||||
if not kernel.SetEvent(handle):
|
||||
raise ctypes.WinError()
|
||||
return True
|
||||
finally:
|
||||
kernel.CloseHandle(handle)
|
||||
+12
-14
@@ -390,20 +390,18 @@ class ManagedProcessRuntime(Generic[_StartOptionsT]):
|
||||
# not an individual process, and can interrupt the caller when a
|
||||
# detached/no-window child has no addressable console group. Keep
|
||||
# termination scoped to the recorded PID tree instead.
|
||||
self._subprocess_run(
|
||||
["taskkill", "/PID", str(pid), "/T"],
|
||||
check=False,
|
||||
stdout=subprocess.DEVNULL,
|
||||
stderr=subprocess.DEVNULL,
|
||||
)
|
||||
if self._wait_for_exit(pid, timeout_s):
|
||||
return True
|
||||
self._subprocess_run(
|
||||
["taskkill", "/PID", str(pid), "/T", "/F"],
|
||||
check=False,
|
||||
stdout=subprocess.DEVNULL,
|
||||
stderr=subprocess.DEVNULL,
|
||||
)
|
||||
# Cooperative shutdown belongs to the application owner. Non-forced
|
||||
# taskkill cannot close these windowless trees and only wastes its grace period.
|
||||
try:
|
||||
self._subprocess_run(
|
||||
["taskkill", "/PID", str(pid), "/T", "/F"],
|
||||
check=False,
|
||||
stdout=subprocess.DEVNULL,
|
||||
stderr=subprocess.DEVNULL,
|
||||
timeout=2,
|
||||
)
|
||||
except subprocess.TimeoutExpired:
|
||||
return False
|
||||
return self._wait_for_exit(pid, 2)
|
||||
|
||||
def _wait_for_exit(self, pid: int, timeout_s: int | float) -> bool:
|
||||
|
||||
@@ -21,7 +21,7 @@ from nanobot.gateway import (
|
||||
RuntimeResult,
|
||||
)
|
||||
from nanobot.gateway.runtime import monitor_gateway_clients
|
||||
from nanobot.process_runtime import process_is_running
|
||||
from nanobot.process_runtime import ManagedProcessRuntime, process_is_running
|
||||
from nanobot.utils.rotating_output import (
|
||||
BACKGROUND_LOG_BACKUP_COUNT_ENV,
|
||||
BACKGROUND_LOG_MAX_BYTES_ENV,
|
||||
@@ -1263,7 +1263,7 @@ def test_terminate_windows_targets_only_the_recorded_process_tree(tmp_path, monk
|
||||
def fake_run(command, **kwargs):
|
||||
taskkill_calls.append({"command": command, "kwargs": kwargs})
|
||||
|
||||
runtime = GatewayRuntime(
|
||||
runtime = ManagedProcessRuntime(
|
||||
paths=_paths(tmp_path),
|
||||
platform_name="Windows",
|
||||
subprocess_run=fake_run,
|
||||
@@ -1277,25 +1277,63 @@ def test_terminate_windows_targets_only_the_recorded_process_tree(tmp_path, monk
|
||||
|
||||
def fake_wait_for_exit(_pid, _timeout_s):
|
||||
wait_timeouts.append(_timeout_s)
|
||||
# Simulate a process that only exits after the taskkill fallback runs.
|
||||
# Simulate a process that exits only after its tree is forcibly terminated.
|
||||
return bool(taskkill_calls)
|
||||
|
||||
monkeypatch.setattr(runtime, "_wait_for_exit", fake_wait_for_exit)
|
||||
|
||||
assert runtime._terminate_windows(12345, timeout_s=20) is True
|
||||
assert wait_timeouts == [20]
|
||||
assert wait_timeouts == [2]
|
||||
assert taskkill_calls == [
|
||||
{
|
||||
"command": ["taskkill", "/PID", "12345", "/T"],
|
||||
"command": ["taskkill", "/PID", "12345", "/T", "/F"],
|
||||
"kwargs": {
|
||||
"check": False,
|
||||
"stdout": subprocess.DEVNULL,
|
||||
"stderr": subprocess.DEVNULL,
|
||||
"timeout": 2,
|
||||
},
|
||||
}
|
||||
]
|
||||
|
||||
|
||||
def test_orphan_shutdown_yields_to_an_explicit_lifecycle_transition(tmp_path):
|
||||
runtime = GatewayRuntime(paths=_paths(tmp_path))
|
||||
lease = GatewayClientLease(runtime, kind="gateway-monitor")
|
||||
lease.mark_ephemeral()
|
||||
|
||||
with runtime._transition_lock():
|
||||
assert lease.begin_orphan_shutdown() is False
|
||||
assert "stopping" not in json.loads(lease.state_path.read_text(encoding="utf-8"))
|
||||
|
||||
assert lease.begin_orphan_shutdown() is True
|
||||
|
||||
|
||||
def test_windows_stop_does_not_force_a_pid_reused_during_grace(tmp_path, monkeypatch):
|
||||
killed = []
|
||||
runtime = GatewayRuntime(
|
||||
paths=_paths(tmp_path), platform_name="Windows",
|
||||
subprocess_run=lambda *args, **kwargs: killed.append(args),
|
||||
)
|
||||
identity = "original-process"
|
||||
runtime._write_state({"pid": 12345, "identity": identity, "shutdown_token": "a" * 32})
|
||||
monkeypatch.setattr(runtime, "_process_identity", lambda _pid: identity)
|
||||
monkeypatch.setattr(runtime, "_is_pid_running", lambda _pid: True)
|
||||
monkeypatch.setattr("nanobot.gateway.runtime.request_windows_shutdown", lambda *_args: True)
|
||||
|
||||
def exit_and_reuse_pid(_pid, _timeout):
|
||||
nonlocal identity
|
||||
identity = "replacement-process"
|
||||
return False
|
||||
|
||||
monkeypatch.setattr(runtime, "_wait_for_exit", exit_and_reuse_pid)
|
||||
|
||||
result = runtime.stop(timeout_s=1)
|
||||
|
||||
assert result.status.running is False
|
||||
assert killed == []
|
||||
|
||||
|
||||
@pytest.mark.skipif(sys.platform == "win32", reason="POSIX process groups are unavailable")
|
||||
def test_terminate_posix_tolerates_process_group_disappearing_before_sigkill(
|
||||
tmp_path,
|
||||
|
||||
@@ -0,0 +1,272 @@
|
||||
"""Exercise Windows gateway shutdown through real, isolated CLI processes."""
|
||||
|
||||
import asyncio
|
||||
import ctypes
|
||||
import http.client
|
||||
import json
|
||||
import os
|
||||
import socket
|
||||
import subprocess
|
||||
import sys
|
||||
import time
|
||||
from ctypes import wintypes
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
from nanobot.gateway import (
|
||||
GatewayInstance,
|
||||
GatewayRuntime,
|
||||
GatewayRuntimePaths,
|
||||
GatewayStartOptions,
|
||||
)
|
||||
from nanobot.gateway.windows_shutdown import WindowsShutdownEvent, request_windows_shutdown
|
||||
|
||||
pytestmark = pytest.mark.skipif(sys.platform != "win32", reason="Windows process lifecycle")
|
||||
|
||||
|
||||
def test_windowless_gateway_stop_runs_application_cleanup(tmp_path: Path) -> None:
|
||||
root = Path(__file__).resolve().parents[2]
|
||||
with socket.socket() as reservation:
|
||||
reservation.bind(("127.0.0.1", 0))
|
||||
port = reservation.getsockname()[1]
|
||||
config_path = tmp_path / "config.json"
|
||||
config_path.write_text(json.dumps({
|
||||
"agents": {"defaults": {
|
||||
"workspace": str(tmp_path / "workspace"),
|
||||
"model": "openai/test-only",
|
||||
"dream": {"enabled": False},
|
||||
}},
|
||||
"providers": {"openai": {"apiKey": "test-only", "apiBase": "http://127.0.0.1:9/v1"}},
|
||||
"gateway": {"host": "127.0.0.1", "port": port, "heartbeat": {"enabled": False}},
|
||||
"channels": {"websocket": {"enabled": False}},
|
||||
}), encoding="utf-8")
|
||||
runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=config_path).paths)
|
||||
env = {**os.environ, "PYTHONPATH": str(root), "PYTHONUTF8": "1"}
|
||||
log_path = tmp_path / "gateway.log"
|
||||
with log_path.open("w", encoding="utf-8") as output:
|
||||
process = subprocess.Popen(
|
||||
[sys.executable, "-m", "nanobot", "gateway", "--foreground", "--config", str(config_path)],
|
||||
cwd=root,
|
||||
env=env,
|
||||
stdin=subprocess.DEVNULL,
|
||||
stdout=output,
|
||||
stderr=subprocess.STDOUT,
|
||||
creationflags=subprocess.CREATE_NO_WINDOW | subprocess.CREATE_NEW_PROCESS_GROUP,
|
||||
)
|
||||
try:
|
||||
deadline = time.monotonic() + 20
|
||||
while True:
|
||||
connection = http.client.HTTPConnection("127.0.0.1", port, timeout=0.2)
|
||||
try:
|
||||
connection.request("GET", "/health")
|
||||
if connection.getresponse().status == 200:
|
||||
break
|
||||
except (OSError, http.client.HTTPException):
|
||||
pass
|
||||
finally:
|
||||
connection.close()
|
||||
assert process.poll() is None, log_path.read_text(encoding="utf-8")
|
||||
assert time.monotonic() < deadline, log_path.read_text(encoding="utf-8")
|
||||
time.sleep(0.02)
|
||||
stopped = subprocess.run(
|
||||
[sys.executable, "-m", "nanobot", "gateway", "stop", "--config", str(config_path)],
|
||||
cwd=root,
|
||||
env=env,
|
||||
capture_output=True,
|
||||
text=True,
|
||||
encoding="utf-8",
|
||||
timeout=30,
|
||||
)
|
||||
assert stopped.returncode == 0, stopped.stdout + stopped.stderr
|
||||
assert "Gateway stopped" in stopped.stdout
|
||||
assert process.wait(timeout=5) == 0, log_path.read_text(encoding="utf-8")
|
||||
assert "Agent loop stopping" in log_path.read_text(encoding="utf-8")
|
||||
assert not runtime.paths.state_path.exists()
|
||||
finally:
|
||||
if process.poll() is None:
|
||||
runtime.stop(timeout_s=0)
|
||||
process.wait(timeout=5)
|
||||
|
||||
|
||||
def _event_security(handle: int) -> str:
|
||||
"""Verify the native owner identity and return the event's rendered security."""
|
||||
security = ctypes.WinDLL("advapi32", use_last_error=True)
|
||||
kernel = ctypes.WinDLL("kernel32", use_last_error=True)
|
||||
kernel.GetCurrentProcess.restype = wintypes.HANDLE
|
||||
kernel.CloseHandle.argtypes = [wintypes.HANDLE]
|
||||
kernel.CloseHandle.restype = wintypes.BOOL
|
||||
security.OpenProcessToken.argtypes = [
|
||||
wintypes.HANDLE, wintypes.DWORD, ctypes.POINTER(wintypes.HANDLE),
|
||||
]
|
||||
security.OpenProcessToken.restype = wintypes.BOOL
|
||||
security.GetTokenInformation.argtypes = [
|
||||
wintypes.HANDLE, ctypes.c_int, wintypes.LPVOID, wintypes.DWORD,
|
||||
ctypes.POINTER(wintypes.DWORD),
|
||||
]
|
||||
security.GetTokenInformation.restype = wintypes.BOOL
|
||||
security.EqualSid.argtypes = [wintypes.LPVOID, wintypes.LPVOID]
|
||||
security.EqualSid.restype = wintypes.BOOL
|
||||
security.GetSecurityInfo.argtypes = [
|
||||
wintypes.HANDLE, ctypes.c_int, wintypes.DWORD,
|
||||
wintypes.LPVOID, wintypes.LPVOID, wintypes.LPVOID, wintypes.LPVOID,
|
||||
ctypes.POINTER(wintypes.LPVOID),
|
||||
]
|
||||
security.GetSecurityInfo.restype = wintypes.DWORD
|
||||
security.ConvertSecurityDescriptorToStringSecurityDescriptorW.argtypes = [
|
||||
wintypes.LPVOID, wintypes.DWORD, wintypes.DWORD,
|
||||
ctypes.POINTER(wintypes.LPWSTR), wintypes.LPVOID,
|
||||
]
|
||||
security.ConvertSecurityDescriptorToStringSecurityDescriptorW.restype = wintypes.BOOL
|
||||
kernel.LocalFree.argtypes = [wintypes.LPVOID]
|
||||
kernel.LocalFree.restype = wintypes.LPVOID
|
||||
descriptor = wintypes.LPVOID()
|
||||
owner = wintypes.LPVOID()
|
||||
text = wintypes.LPWSTR()
|
||||
token = wintypes.HANDLE()
|
||||
try:
|
||||
assert security.GetSecurityInfo(
|
||||
handle, 6, 5, ctypes.byref(owner), None, None, None, ctypes.byref(descriptor),
|
||||
) == 0
|
||||
assert security.OpenProcessToken(kernel.GetCurrentProcess(), 0x0008, ctypes.byref(token))
|
||||
size = wintypes.DWORD()
|
||||
security.GetTokenInformation(token, 1, None, 0, ctypes.byref(size)) # TokenUser
|
||||
assert size.value > 0
|
||||
user = ctypes.create_string_buffer(size.value)
|
||||
assert security.GetTokenInformation(token, 1, user, len(user), ctypes.byref(size))
|
||||
current_user = ctypes.cast(user, ctypes.POINTER(wintypes.LPVOID))[0]
|
||||
# SDDL may abbreviate account SIDs (for example LA); compare their identities.
|
||||
assert security.EqualSid(owner, current_user)
|
||||
assert security.ConvertSecurityDescriptorToStringSecurityDescriptorW(
|
||||
descriptor, 1, 5, ctypes.byref(text), None,
|
||||
)
|
||||
assert text.value is not None
|
||||
return text.value
|
||||
finally:
|
||||
if text:
|
||||
kernel.LocalFree(text)
|
||||
if descriptor:
|
||||
kernel.LocalFree(descriptor)
|
||||
if token:
|
||||
kernel.CloseHandle(token)
|
||||
|
||||
|
||||
def test_shutdown_signal_is_private_process_bound_and_latched(tmp_path: Path) -> None:
|
||||
runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path))
|
||||
pid = os.getpid()
|
||||
identity = runtime.process_identity(pid)
|
||||
assert isinstance(identity, str)
|
||||
with runtime.foreground_instance(GatewayStartOptions(port=0)):
|
||||
state = json.loads(runtime.paths.state_path.read_text(encoding="utf-8"))
|
||||
token = state["shutdown_token"]
|
||||
signal = runtime._shutdown_signal
|
||||
assert signal is not None and signal._handle is not None
|
||||
owner, dacl = _event_security(signal._handle)[2:].split("D:", 1)
|
||||
assert dacl.startswith("P(A;;") and dacl.endswith(f";;;{owner})")
|
||||
assert dacl.count("(") == 1 # One owner-only allow ACE, no inherited grants.
|
||||
assert request_windows_shutdown(pid + 1, identity, token) is False
|
||||
assert request_windows_shutdown(pid, identity + "1", token) is False
|
||||
other = WindowsShutdownEvent(pid, identity)
|
||||
try:
|
||||
other_name = rf"Local\nanobot-gateway-stop-{pid}-{identity}-{other.token}"
|
||||
assert request_windows_shutdown(pid, identity, other_name) is False
|
||||
kernel = ctypes.WinDLL("kernel32", use_last_error=True)
|
||||
kernel.WaitForSingleObject.argtypes = [wintypes.HANDLE, wintypes.DWORD]
|
||||
kernel.WaitForSingleObject.restype = wintypes.DWORD
|
||||
assert kernel.WaitForSingleObject(other._handle, 0) == 258 # Still unsignaled.
|
||||
finally:
|
||||
other.close()
|
||||
assert request_windows_shutdown(pid, identity, token) is True
|
||||
shutdown = asyncio.Event()
|
||||
asyncio.run(runtime.wait_for_shutdown_request(shutdown))
|
||||
assert shutdown.is_set()
|
||||
assert request_windows_shutdown(pid, identity, token) is False
|
||||
|
||||
|
||||
def test_cancelling_shutdown_listener_drains_its_native_wait(tmp_path: Path) -> None:
|
||||
runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path))
|
||||
with runtime.foreground_instance(GatewayStartOptions(port=0)):
|
||||
async def cancel_listener() -> None:
|
||||
shutdown = asyncio.Event()
|
||||
listener = asyncio.create_task(runtime.wait_for_shutdown_request(shutdown))
|
||||
await asyncio.sleep(0) # Admit the wait before exercising ordinary runtime cancellation.
|
||||
listener.cancel()
|
||||
with pytest.raises(asyncio.CancelledError):
|
||||
await asyncio.wait_for(listener, timeout=2)
|
||||
assert not shutdown.is_set()
|
||||
|
||||
asyncio.run(cancel_listener())
|
||||
assert runtime._shutdown_signal is None
|
||||
|
||||
|
||||
def test_failed_foreground_publication_closes_shutdown_signal(tmp_path: Path, monkeypatch) -> None:
|
||||
runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path))
|
||||
signals = []
|
||||
|
||||
def create_signal(pid, identity):
|
||||
signal = WindowsShutdownEvent(pid, identity)
|
||||
signals.append(signal)
|
||||
return signal
|
||||
|
||||
def fail_write(_state):
|
||||
raise OSError("cannot publish state")
|
||||
|
||||
monkeypatch.setattr("nanobot.gateway.runtime.WindowsShutdownEvent", create_signal)
|
||||
monkeypatch.setattr(runtime, "_write_state", fail_write)
|
||||
with pytest.raises(OSError, match="cannot publish state"):
|
||||
with runtime.foreground_instance(GatewayStartOptions(port=0)):
|
||||
pytest.fail("failed publication must not enter the foreground runtime")
|
||||
assert len(signals) == 1 and signals[0]._handle is None
|
||||
assert runtime._shutdown_signal is None
|
||||
|
||||
|
||||
_STALLED_GATEWAY = r"""
|
||||
import json, subprocess, sys, time
|
||||
from pathlib import Path
|
||||
from nanobot.gateway import GatewayInstance, GatewayRuntime, GatewayStartOptions
|
||||
|
||||
root = Path(sys.argv[1])
|
||||
runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=root / 'config.json').paths)
|
||||
with runtime.foreground_instance(GatewayStartOptions(port=0)):
|
||||
child = subprocess.Popen([sys._base_executable, '-c', 'import time; time.sleep(60)'])
|
||||
(root / 'ready.json').write_text(json.dumps({'child': child.pid}), encoding='utf-8')
|
||||
time.sleep(60) # Models a blocked event loop that cannot service the kernel event.
|
||||
"""
|
||||
|
||||
|
||||
@pytest.mark.parametrize("published", [True, False], ids=["stalled", "no-signal"])
|
||||
def test_windows_stop_forces_only_its_stalled_tree(tmp_path: Path, published: bool) -> None:
|
||||
runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=tmp_path / "config.json").paths)
|
||||
root = Path(__file__).resolve().parents[2]
|
||||
env = {**os.environ, "PYTHONPATH": str(root)}
|
||||
process = subprocess.Popen(
|
||||
[sys.executable, "-c", _STALLED_GATEWAY, str(tmp_path)], env=env,
|
||||
stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL,
|
||||
creationflags=subprocess.CREATE_NO_WINDOW | subprocess.CREATE_NEW_PROCESS_GROUP,
|
||||
)
|
||||
ready = tmp_path / "ready.json"
|
||||
try:
|
||||
deadline = time.monotonic() + 5
|
||||
while not ready.exists():
|
||||
assert process.poll() is None
|
||||
assert time.monotonic() < deadline
|
||||
time.sleep(0.01)
|
||||
child_pid = json.loads(ready.read_text(encoding="utf-8"))["child"]
|
||||
state = json.loads(runtime.paths.state_path.read_text(encoding="utf-8"))
|
||||
if not published:
|
||||
state.pop("shutdown_token")
|
||||
runtime._write_state(state)
|
||||
started = time.monotonic()
|
||||
result = runtime.stop(timeout_s=1 if published else 20)
|
||||
elapsed = time.monotonic() - started
|
||||
assert result.ok
|
||||
assert process.wait(timeout=5) != 0
|
||||
assert not runtime.process_is_running(child_pid)
|
||||
assert not runtime.paths.state_path.exists()
|
||||
assert elapsed < 5 # Missing signals must not consume the 20-second grace.
|
||||
if published:
|
||||
assert elapsed >= 1 # A delivered request retains the caller's grace period.
|
||||
finally:
|
||||
if process.poll() is None:
|
||||
runtime.stop(timeout_s=0)
|
||||
process.wait(timeout=5)
|
||||
Reference in new issue
Block a user