diff --git a/docs/cli-reference.md b/docs/cli-reference.md index a9c013402..2f0731ea8 100644 --- a/docs/cli-reference.md +++ b/docs/cli-reference.md @@ -170,6 +170,8 @@ First-run WebUI setup binds to `127.0.0.1` by default. Use manual configuration | `nanobot gateway install-service --dry-run` | Preview the generated service file and system commands | | `nanobot gateway uninstall-service` | Remove the installed system service | +On Windows, `gateway stop` waits up to `--timeout` seconds (default: 20) for the gateway to stop normally. If a forced stop is needed, the command displays a warning. Forced stops can interrupt active work. + For custom instances, pass the same selector flags after the management subcommand, as shown below. `--config` and `--workspace` before a management subcommand are rejected with a usage error; they are not inherited. ```bash diff --git a/nanobot/cli/gateway_runtime.py b/nanobot/cli/gateway_runtime.py index 29d75bb5f..af1d2c8a1 100644 --- a/nanobot/cli/gateway_runtime.py +++ b/nanobot/cli/gateway_runtime.py @@ -980,6 +980,10 @@ def _run_gateway( logger.info("Last local client disappeared; stopping on-demand gateway") tasks.extend([ + asyncio.create_task( + gateway_runtime.wait_for_shutdown_request(shutdown_event), + name="nanobot-gateway-stop-request", + ), asyncio.create_task( watch_config_file( Path(config_path), diff --git a/nanobot/gateway/runtime.py b/nanobot/gateway/runtime.py index e6919a185..72a8fdaa6 100644 --- a/nanobot/gateway/runtime.py +++ b/nanobot/gateway/runtime.py @@ -20,10 +20,12 @@ from datetime import UTC, datetime from pathlib import Path from typing import Any, Generator, Literal, cast -from filelock import FileLock +from filelock import FileLock, Timeout +from loguru import logger from nanobot.config.home import get_selected_home_path from nanobot.config.paths import get_data_dir +from nanobot.gateway.windows_shutdown import WindowsShutdownEvent, request_windows_shutdown from nanobot.process_runtime import ( ManagedProcessRuntime, ProcessResult, @@ -235,6 +237,7 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]): subprocess_run=subprocess_run, sleep=sleep, ) + self._shutdown_signal: WindowsShutdownEvent | None = None def _build_child_command(self, options: GatewayStartOptions) -> list[str]: return build_gateway_command(self.python_executable, options) @@ -339,12 +342,66 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]): @contextmanager def foreground_instance(self, options: GatewayStartOptions) -> Generator[None]: - """Publish this foreground gateway while it is available to local clients.""" - self._claim_current_process(options) + """Publish this process and own its stop signal across asyncio.run().""" + shutdown_signal = None + if self.platform_name == "Windows" and os.name == "nt": + identity = self.process_identity(os.getpid()) + if not isinstance(identity, str): + raise OSError("Cannot identify the gateway process for Windows shutdown") + shutdown_signal = WindowsShutdownEvent(os.getpid(), identity) + self._shutdown_signal = shutdown_signal try: - yield + self._claim_current_process(options) + try: + yield + finally: + self._release_current_process() finally: - self._release_current_process() + self._shutdown_signal = None + if shutdown_signal is not None: + shutdown_signal.close() + + async def wait_for_shutdown_request(self, shutdown_event: asyncio.Event) -> None: + """Bridge the local Windows signal to the application's existing shutdown.""" + signal = self._shutdown_signal + if signal is None: + return + waiter = asyncio.create_task(asyncio.to_thread(signal.wait)) + try: + await asyncio.shield(waiter) + logger.info("Gateway shutdown requested by local CLI") + shutdown_event.set() + finally: + # Cancelling to_thread alone leaves its native wait alive. Wake it + # before asyncio.run drains the executor and the owner closes the handle. + signal.signal() + await waiter + + def _terminate_windows(self, pid: int, *, timeout_s: int) -> bool: + state = self._read_state() + identity = self._process_identity(pid) + if identity is None: + return not self._is_pid_running(pid) + if self._process_identity_match(state, pid) != "match": + return False + requested = False + if isinstance(identity, str) and state is not None: + try: + requested = request_windows_shutdown(pid, identity, state.get("shutdown_token")) + except OSError as exc: + logger.warning("Could not request gateway shutdown: {}", exc) + if requested and self._wait_for_exit(pid, timeout_s): + return True + current_identity = self._process_identity(pid) + if current_identity is None: + return not self._is_pid_running(pid) + if current_identity != identity: + return False + if requested: + logger.warning("Gateway did not exit within {}s; forcing PID tree {}", timeout_s, pid) + else: + logger.warning("Gateway shutdown signal unavailable; forcing PID tree {}", pid) + return super()._terminate_windows(pid, timeout_s=timeout_s) def _claim_current_process(self, options: GatewayStartOptions) -> GatewayLaunchMode: lease = GatewayClientLease(self, kind="gateway-foreground") @@ -389,6 +446,9 @@ class GatewayRuntime(ManagedProcessRuntime[GatewayStartOptions]): state.pop("pending_pid_handoff", None) state.pop("stable_identity", None) state.update(self.process_identity_record(pid)) + state.pop("shutdown_token", None) + if self._shutdown_signal is not None: + state["shutdown_token"] = self._shutdown_signal.token self._write_state(state) if launch_mode == "foreground": lease._try_mark_persistent_locked() @@ -521,7 +581,13 @@ class GatewayClientLease: def begin_orphan_shutdown(self) -> bool: """Commit shutdown only while an on-demand gateway still has no clients.""" - with self.transition_lock, self.lifecycle_lock, self.lock: + # Explicit stop holds this lock while waiting for us to exit. Never + # block the gateway loop (or an executor being drained) behind it. + try: + transition = self.transition_lock.acquire(timeout=0) + except Timeout: + return False + with transition, self.lifecycle_lock, self.lock: state = self._live_state() if not bool(state.get("auto_stop")) or self._clients(state): self._write_or_clear(state) diff --git a/nanobot/gateway/windows_shutdown.py b/nanobot/gateway/windows_shutdown.py new file mode 100644 index 000000000..92dd1e77c --- /dev/null +++ b/nanobot/gateway/windows_shutdown.py @@ -0,0 +1,149 @@ +"""User-private, process-bound Windows gateway shutdown signals.""" + +from __future__ import annotations + +import ctypes +import re +import uuid +from collections.abc import Generator +from contextlib import contextmanager +from ctypes import wintypes +from functools import lru_cache +from typing import Any + + +class _SecurityAttributes(ctypes.Structure): + _fields_ = [ + ("length", wintypes.DWORD), + ("descriptor", wintypes.LPVOID), + ("inherit", wintypes.BOOL), + ] + + +@lru_cache(maxsize=1) +def _kernel32() -> Any: + kernel = ctypes.WinDLL("kernel32", use_last_error=True) + kernel.GetCurrentProcess.restype = wintypes.HANDLE + kernel.CreateEventW.argtypes = [ + ctypes.POINTER(_SecurityAttributes), wintypes.BOOL, wintypes.BOOL, wintypes.LPCWSTR, + ] + kernel.CreateEventW.restype = wintypes.HANDLE + kernel.OpenEventW.argtypes = [wintypes.DWORD, wintypes.BOOL, wintypes.LPCWSTR] + kernel.OpenEventW.restype = wintypes.HANDLE + kernel.SetEvent.argtypes = [wintypes.HANDLE] + kernel.SetEvent.restype = wintypes.BOOL + kernel.WaitForSingleObject.argtypes = [wintypes.HANDLE, wintypes.DWORD] + kernel.WaitForSingleObject.restype = wintypes.DWORD + kernel.CloseHandle.argtypes = [wintypes.HANDLE] + kernel.CloseHandle.restype = wintypes.BOOL + kernel.LocalFree.argtypes = [wintypes.LPVOID] + kernel.LocalFree.restype = wintypes.LPVOID + return kernel + + +@contextmanager +def _private_security() -> Generator[_SecurityAttributes]: + kernel = _kernel32() + security = ctypes.WinDLL("advapi32", use_last_error=True) + security.OpenProcessToken.argtypes = [ + wintypes.HANDLE, wintypes.DWORD, ctypes.POINTER(wintypes.HANDLE), + ] + security.OpenProcessToken.restype = wintypes.BOOL + security.GetTokenInformation.argtypes = [ + wintypes.HANDLE, ctypes.c_int, wintypes.LPVOID, wintypes.DWORD, + ctypes.POINTER(wintypes.DWORD), + ] + security.GetTokenInformation.restype = wintypes.BOOL + security.ConvertSidToStringSidW.argtypes = [ + wintypes.LPVOID, ctypes.POINTER(wintypes.LPWSTR), + ] + security.ConvertSidToStringSidW.restype = wintypes.BOOL + security.ConvertStringSecurityDescriptorToSecurityDescriptorW.argtypes = [ + wintypes.LPCWSTR, wintypes.DWORD, ctypes.POINTER(wintypes.LPVOID), wintypes.LPVOID, + ] + security.ConvertStringSecurityDescriptorToSecurityDescriptorW.restype = wintypes.BOOL + token = wintypes.HANDLE() + if not security.OpenProcessToken(kernel.GetCurrentProcess(), 0x0008, ctypes.byref(token)): + raise ctypes.WinError() + sid_text = wintypes.LPWSTR() + descriptor = wintypes.LPVOID() + try: + size = wintypes.DWORD() + security.GetTokenInformation(token, 1, None, 0, ctypes.byref(size)) # TokenUser + if not size.value: + raise ctypes.WinError() + user = ctypes.create_string_buffer(size.value) + if not security.GetTokenInformation(token, 1, user, len(user), ctypes.byref(size)): + raise ctypes.WinError() + sid = ctypes.cast(user, ctypes.POINTER(wintypes.LPVOID))[0] + if not security.ConvertSidToStringSidW(sid, ctypes.byref(sid_text)): + raise ctypes.WinError() + if not security.ConvertStringSecurityDescriptorToSecurityDescriptorW( + f"O:{sid_text.value}D:P(A;;GA;;;{sid_text.value})", 1, + ctypes.byref(descriptor), None, + ): + raise ctypes.WinError() + yield _SecurityAttributes(ctypes.sizeof(_SecurityAttributes), descriptor, False) + finally: + if descriptor: + kernel.LocalFree(descriptor) + if sid_text: + kernel.LocalFree(sid_text) + kernel.CloseHandle(token) + + +def _event_name(pid: int, identity: str, token: str) -> str: + return rf"Local\nanobot-gateway-stop-{pid}-{identity}-{token}" + + +class WindowsShutdownEvent: + """Own one latched signal; close only after the native waiter has drained.""" + + def __init__(self, pid: int, identity: str) -> None: + self.token = uuid.uuid4().hex + kernel = _kernel32() + with _private_security() as security: + ctypes.set_last_error(0) + handle = kernel.CreateEventW( + ctypes.byref(security), True, False, _event_name(pid, identity, self.token), + ) + error = ctypes.get_last_error() + if not handle: + raise ctypes.WinError(error) + if error == 183: # ERROR_ALREADY_EXISTS: the requested DACL was not applied. + kernel.CloseHandle(handle) + raise OSError("Gateway shutdown event already exists") + self._handle: int | None = int(handle) + + def wait(self) -> None: + """Block a worker, never the event loop; signal() also wakes cancellation.""" + if _kernel32().WaitForSingleObject(self._handle, 0xFFFFFFFF) != 0: + raise ctypes.WinError() + + def signal(self) -> None: + if not _kernel32().SetEvent(self._handle): + raise ctypes.WinError() + + def close(self) -> None: + if self._handle is not None: + _kernel32().CloseHandle(self._handle) + self._handle = None + + +def request_windows_shutdown(pid: int, identity: str, token: object) -> bool: + """Signal only a validated token in this exact process-birth namespace.""" + if not isinstance(token, str) or re.fullmatch(r"[0-9a-f]{32}", token) is None: + return False + kernel = _kernel32() + handle = kernel.OpenEventW(0x0002, False, _event_name(pid, identity, token)) + if not handle: + error = ctypes.get_last_error() + if error == 2: # The process exited, or never published this event. + return False + raise ctypes.WinError(error) + try: + if not kernel.SetEvent(handle): + raise ctypes.WinError() + return True + finally: + kernel.CloseHandle(handle) diff --git a/nanobot/process_runtime.py b/nanobot/process_runtime.py index 93bad4cbc..8ef4351d9 100644 --- a/nanobot/process_runtime.py +++ b/nanobot/process_runtime.py @@ -390,20 +390,18 @@ class ManagedProcessRuntime(Generic[_StartOptionsT]): # not an individual process, and can interrupt the caller when a # detached/no-window child has no addressable console group. Keep # termination scoped to the recorded PID tree instead. - self._subprocess_run( - ["taskkill", "/PID", str(pid), "/T"], - check=False, - stdout=subprocess.DEVNULL, - stderr=subprocess.DEVNULL, - ) - if self._wait_for_exit(pid, timeout_s): - return True - self._subprocess_run( - ["taskkill", "/PID", str(pid), "/T", "/F"], - check=False, - stdout=subprocess.DEVNULL, - stderr=subprocess.DEVNULL, - ) + # Cooperative shutdown belongs to the application owner. Non-forced + # taskkill cannot close these windowless trees and only wastes its grace period. + try: + self._subprocess_run( + ["taskkill", "/PID", str(pid), "/T", "/F"], + check=False, + stdout=subprocess.DEVNULL, + stderr=subprocess.DEVNULL, + timeout=2, + ) + except subprocess.TimeoutExpired: + return False return self._wait_for_exit(pid, 2) def _wait_for_exit(self, pid: int, timeout_s: int | float) -> bool: diff --git a/tests/gateway/test_runtime.py b/tests/gateway/test_runtime.py index ef03d57e2..8db5963ba 100644 --- a/tests/gateway/test_runtime.py +++ b/tests/gateway/test_runtime.py @@ -21,7 +21,7 @@ from nanobot.gateway import ( RuntimeResult, ) from nanobot.gateway.runtime import monitor_gateway_clients -from nanobot.process_runtime import process_is_running +from nanobot.process_runtime import ManagedProcessRuntime, process_is_running from nanobot.utils.rotating_output import ( BACKGROUND_LOG_BACKUP_COUNT_ENV, BACKGROUND_LOG_MAX_BYTES_ENV, @@ -1263,7 +1263,7 @@ def test_terminate_windows_targets_only_the_recorded_process_tree(tmp_path, monk def fake_run(command, **kwargs): taskkill_calls.append({"command": command, "kwargs": kwargs}) - runtime = GatewayRuntime( + runtime = ManagedProcessRuntime( paths=_paths(tmp_path), platform_name="Windows", subprocess_run=fake_run, @@ -1277,25 +1277,63 @@ def test_terminate_windows_targets_only_the_recorded_process_tree(tmp_path, monk def fake_wait_for_exit(_pid, _timeout_s): wait_timeouts.append(_timeout_s) - # Simulate a process that only exits after the taskkill fallback runs. + # Simulate a process that exits only after its tree is forcibly terminated. return bool(taskkill_calls) monkeypatch.setattr(runtime, "_wait_for_exit", fake_wait_for_exit) assert runtime._terminate_windows(12345, timeout_s=20) is True - assert wait_timeouts == [20] + assert wait_timeouts == [2] assert taskkill_calls == [ { - "command": ["taskkill", "/PID", "12345", "/T"], + "command": ["taskkill", "/PID", "12345", "/T", "/F"], "kwargs": { "check": False, "stdout": subprocess.DEVNULL, "stderr": subprocess.DEVNULL, + "timeout": 2, }, } ] +def test_orphan_shutdown_yields_to_an_explicit_lifecycle_transition(tmp_path): + runtime = GatewayRuntime(paths=_paths(tmp_path)) + lease = GatewayClientLease(runtime, kind="gateway-monitor") + lease.mark_ephemeral() + + with runtime._transition_lock(): + assert lease.begin_orphan_shutdown() is False + assert "stopping" not in json.loads(lease.state_path.read_text(encoding="utf-8")) + + assert lease.begin_orphan_shutdown() is True + + +def test_windows_stop_does_not_force_a_pid_reused_during_grace(tmp_path, monkeypatch): + killed = [] + runtime = GatewayRuntime( + paths=_paths(tmp_path), platform_name="Windows", + subprocess_run=lambda *args, **kwargs: killed.append(args), + ) + identity = "original-process" + runtime._write_state({"pid": 12345, "identity": identity, "shutdown_token": "a" * 32}) + monkeypatch.setattr(runtime, "_process_identity", lambda _pid: identity) + monkeypatch.setattr(runtime, "_is_pid_running", lambda _pid: True) + monkeypatch.setattr("nanobot.gateway.runtime.request_windows_shutdown", lambda *_args: True) + + def exit_and_reuse_pid(_pid, _timeout): + nonlocal identity + identity = "replacement-process" + return False + + monkeypatch.setattr(runtime, "_wait_for_exit", exit_and_reuse_pid) + + result = runtime.stop(timeout_s=1) + + assert result.status.running is False + assert killed == [] + + @pytest.mark.skipif(sys.platform == "win32", reason="POSIX process groups are unavailable") def test_terminate_posix_tolerates_process_group_disappearing_before_sigkill( tmp_path, diff --git a/tests/gateway/test_windows_shutdown.py b/tests/gateway/test_windows_shutdown.py new file mode 100644 index 000000000..78cbe453b --- /dev/null +++ b/tests/gateway/test_windows_shutdown.py @@ -0,0 +1,272 @@ +"""Exercise Windows gateway shutdown through real, isolated CLI processes.""" + +import asyncio +import ctypes +import http.client +import json +import os +import socket +import subprocess +import sys +import time +from ctypes import wintypes +from pathlib import Path + +import pytest + +from nanobot.gateway import ( + GatewayInstance, + GatewayRuntime, + GatewayRuntimePaths, + GatewayStartOptions, +) +from nanobot.gateway.windows_shutdown import WindowsShutdownEvent, request_windows_shutdown + +pytestmark = pytest.mark.skipif(sys.platform != "win32", reason="Windows process lifecycle") + + +def test_windowless_gateway_stop_runs_application_cleanup(tmp_path: Path) -> None: + root = Path(__file__).resolve().parents[2] + with socket.socket() as reservation: + reservation.bind(("127.0.0.1", 0)) + port = reservation.getsockname()[1] + config_path = tmp_path / "config.json" + config_path.write_text(json.dumps({ + "agents": {"defaults": { + "workspace": str(tmp_path / "workspace"), + "model": "openai/test-only", + "dream": {"enabled": False}, + }}, + "providers": {"openai": {"apiKey": "test-only", "apiBase": "http://127.0.0.1:9/v1"}}, + "gateway": {"host": "127.0.0.1", "port": port, "heartbeat": {"enabled": False}}, + "channels": {"websocket": {"enabled": False}}, + }), encoding="utf-8") + runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=config_path).paths) + env = {**os.environ, "PYTHONPATH": str(root), "PYTHONUTF8": "1"} + log_path = tmp_path / "gateway.log" + with log_path.open("w", encoding="utf-8") as output: + process = subprocess.Popen( + [sys.executable, "-m", "nanobot", "gateway", "--foreground", "--config", str(config_path)], + cwd=root, + env=env, + stdin=subprocess.DEVNULL, + stdout=output, + stderr=subprocess.STDOUT, + creationflags=subprocess.CREATE_NO_WINDOW | subprocess.CREATE_NEW_PROCESS_GROUP, + ) + try: + deadline = time.monotonic() + 20 + while True: + connection = http.client.HTTPConnection("127.0.0.1", port, timeout=0.2) + try: + connection.request("GET", "/health") + if connection.getresponse().status == 200: + break + except (OSError, http.client.HTTPException): + pass + finally: + connection.close() + assert process.poll() is None, log_path.read_text(encoding="utf-8") + assert time.monotonic() < deadline, log_path.read_text(encoding="utf-8") + time.sleep(0.02) + stopped = subprocess.run( + [sys.executable, "-m", "nanobot", "gateway", "stop", "--config", str(config_path)], + cwd=root, + env=env, + capture_output=True, + text=True, + encoding="utf-8", + timeout=30, + ) + assert stopped.returncode == 0, stopped.stdout + stopped.stderr + assert "Gateway stopped" in stopped.stdout + assert process.wait(timeout=5) == 0, log_path.read_text(encoding="utf-8") + assert "Agent loop stopping" in log_path.read_text(encoding="utf-8") + assert not runtime.paths.state_path.exists() + finally: + if process.poll() is None: + runtime.stop(timeout_s=0) + process.wait(timeout=5) + + +def _event_security(handle: int) -> str: + """Verify the native owner identity and return the event's rendered security.""" + security = ctypes.WinDLL("advapi32", use_last_error=True) + kernel = ctypes.WinDLL("kernel32", use_last_error=True) + kernel.GetCurrentProcess.restype = wintypes.HANDLE + kernel.CloseHandle.argtypes = [wintypes.HANDLE] + kernel.CloseHandle.restype = wintypes.BOOL + security.OpenProcessToken.argtypes = [ + wintypes.HANDLE, wintypes.DWORD, ctypes.POINTER(wintypes.HANDLE), + ] + security.OpenProcessToken.restype = wintypes.BOOL + security.GetTokenInformation.argtypes = [ + wintypes.HANDLE, ctypes.c_int, wintypes.LPVOID, wintypes.DWORD, + ctypes.POINTER(wintypes.DWORD), + ] + security.GetTokenInformation.restype = wintypes.BOOL + security.EqualSid.argtypes = [wintypes.LPVOID, wintypes.LPVOID] + security.EqualSid.restype = wintypes.BOOL + security.GetSecurityInfo.argtypes = [ + wintypes.HANDLE, ctypes.c_int, wintypes.DWORD, + wintypes.LPVOID, wintypes.LPVOID, wintypes.LPVOID, wintypes.LPVOID, + ctypes.POINTER(wintypes.LPVOID), + ] + security.GetSecurityInfo.restype = wintypes.DWORD + security.ConvertSecurityDescriptorToStringSecurityDescriptorW.argtypes = [ + wintypes.LPVOID, wintypes.DWORD, wintypes.DWORD, + ctypes.POINTER(wintypes.LPWSTR), wintypes.LPVOID, + ] + security.ConvertSecurityDescriptorToStringSecurityDescriptorW.restype = wintypes.BOOL + kernel.LocalFree.argtypes = [wintypes.LPVOID] + kernel.LocalFree.restype = wintypes.LPVOID + descriptor = wintypes.LPVOID() + owner = wintypes.LPVOID() + text = wintypes.LPWSTR() + token = wintypes.HANDLE() + try: + assert security.GetSecurityInfo( + handle, 6, 5, ctypes.byref(owner), None, None, None, ctypes.byref(descriptor), + ) == 0 + assert security.OpenProcessToken(kernel.GetCurrentProcess(), 0x0008, ctypes.byref(token)) + size = wintypes.DWORD() + security.GetTokenInformation(token, 1, None, 0, ctypes.byref(size)) # TokenUser + assert size.value > 0 + user = ctypes.create_string_buffer(size.value) + assert security.GetTokenInformation(token, 1, user, len(user), ctypes.byref(size)) + current_user = ctypes.cast(user, ctypes.POINTER(wintypes.LPVOID))[0] + # SDDL may abbreviate account SIDs (for example LA); compare their identities. + assert security.EqualSid(owner, current_user) + assert security.ConvertSecurityDescriptorToStringSecurityDescriptorW( + descriptor, 1, 5, ctypes.byref(text), None, + ) + assert text.value is not None + return text.value + finally: + if text: + kernel.LocalFree(text) + if descriptor: + kernel.LocalFree(descriptor) + if token: + kernel.CloseHandle(token) + + +def test_shutdown_signal_is_private_process_bound_and_latched(tmp_path: Path) -> None: + runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path)) + pid = os.getpid() + identity = runtime.process_identity(pid) + assert isinstance(identity, str) + with runtime.foreground_instance(GatewayStartOptions(port=0)): + state = json.loads(runtime.paths.state_path.read_text(encoding="utf-8")) + token = state["shutdown_token"] + signal = runtime._shutdown_signal + assert signal is not None and signal._handle is not None + owner, dacl = _event_security(signal._handle)[2:].split("D:", 1) + assert dacl.startswith("P(A;;") and dacl.endswith(f";;;{owner})") + assert dacl.count("(") == 1 # One owner-only allow ACE, no inherited grants. + assert request_windows_shutdown(pid + 1, identity, token) is False + assert request_windows_shutdown(pid, identity + "1", token) is False + other = WindowsShutdownEvent(pid, identity) + try: + other_name = rf"Local\nanobot-gateway-stop-{pid}-{identity}-{other.token}" + assert request_windows_shutdown(pid, identity, other_name) is False + kernel = ctypes.WinDLL("kernel32", use_last_error=True) + kernel.WaitForSingleObject.argtypes = [wintypes.HANDLE, wintypes.DWORD] + kernel.WaitForSingleObject.restype = wintypes.DWORD + assert kernel.WaitForSingleObject(other._handle, 0) == 258 # Still unsignaled. + finally: + other.close() + assert request_windows_shutdown(pid, identity, token) is True + shutdown = asyncio.Event() + asyncio.run(runtime.wait_for_shutdown_request(shutdown)) + assert shutdown.is_set() + assert request_windows_shutdown(pid, identity, token) is False + + +def test_cancelling_shutdown_listener_drains_its_native_wait(tmp_path: Path) -> None: + runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path)) + with runtime.foreground_instance(GatewayStartOptions(port=0)): + async def cancel_listener() -> None: + shutdown = asyncio.Event() + listener = asyncio.create_task(runtime.wait_for_shutdown_request(shutdown)) + await asyncio.sleep(0) # Admit the wait before exercising ordinary runtime cancellation. + listener.cancel() + with pytest.raises(asyncio.CancelledError): + await asyncio.wait_for(listener, timeout=2) + assert not shutdown.is_set() + + asyncio.run(cancel_listener()) + assert runtime._shutdown_signal is None + + +def test_failed_foreground_publication_closes_shutdown_signal(tmp_path: Path, monkeypatch) -> None: + runtime = GatewayRuntime(paths=GatewayRuntimePaths.for_instance(data_dir=tmp_path)) + signals = [] + + def create_signal(pid, identity): + signal = WindowsShutdownEvent(pid, identity) + signals.append(signal) + return signal + + def fail_write(_state): + raise OSError("cannot publish state") + + monkeypatch.setattr("nanobot.gateway.runtime.WindowsShutdownEvent", create_signal) + monkeypatch.setattr(runtime, "_write_state", fail_write) + with pytest.raises(OSError, match="cannot publish state"): + with runtime.foreground_instance(GatewayStartOptions(port=0)): + pytest.fail("failed publication must not enter the foreground runtime") + assert len(signals) == 1 and signals[0]._handle is None + assert runtime._shutdown_signal is None + + +_STALLED_GATEWAY = r""" +import json, subprocess, sys, time +from pathlib import Path +from nanobot.gateway import GatewayInstance, GatewayRuntime, GatewayStartOptions + +root = Path(sys.argv[1]) +runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=root / 'config.json').paths) +with runtime.foreground_instance(GatewayStartOptions(port=0)): + child = subprocess.Popen([sys._base_executable, '-c', 'import time; time.sleep(60)']) + (root / 'ready.json').write_text(json.dumps({'child': child.pid}), encoding='utf-8') + time.sleep(60) # Models a blocked event loop that cannot service the kernel event. +""" + + +@pytest.mark.parametrize("published", [True, False], ids=["stalled", "no-signal"]) +def test_windows_stop_forces_only_its_stalled_tree(tmp_path: Path, published: bool) -> None: + runtime = GatewayRuntime(paths=GatewayInstance.resolve(config_path=tmp_path / "config.json").paths) + root = Path(__file__).resolve().parents[2] + env = {**os.environ, "PYTHONPATH": str(root)} + process = subprocess.Popen( + [sys.executable, "-c", _STALLED_GATEWAY, str(tmp_path)], env=env, + stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL, + creationflags=subprocess.CREATE_NO_WINDOW | subprocess.CREATE_NEW_PROCESS_GROUP, + ) + ready = tmp_path / "ready.json" + try: + deadline = time.monotonic() + 5 + while not ready.exists(): + assert process.poll() is None + assert time.monotonic() < deadline + time.sleep(0.01) + child_pid = json.loads(ready.read_text(encoding="utf-8"))["child"] + state = json.loads(runtime.paths.state_path.read_text(encoding="utf-8")) + if not published: + state.pop("shutdown_token") + runtime._write_state(state) + started = time.monotonic() + result = runtime.stop(timeout_s=1 if published else 20) + elapsed = time.monotonic() - started + assert result.ok + assert process.wait(timeout=5) != 0 + assert not runtime.process_is_running(child_pid) + assert not runtime.paths.state_path.exists() + assert elapsed < 5 # Missing signals must not consume the 20-second grace. + if published: + assert elapsed >= 1 # A delivered request retains the caller's grace period. + finally: + if process.poll() is None: + runtime.stop(timeout_s=0) + process.wait(timeout=5)